Description
TOTCT-63 Contactors can be used to remote control applications in alternative networks:
1.lighting,heating,ventilation,roller blinds,sanitary hot water.
2.Mechanical ventilation Systems
3.Load-shedding of non-priority circuits
- Circumstance temperature -5°C ~ +40°C, average temperature within 24h not exceeding +35°C.
- Altitude above sea level less than 2000 m.
- Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
- Installation class II
- Pollution class 2.
- Installation method DIN Rail mounting type.
- Product shall be vertically mounted onto standard Din rail 35mm.
Contactor version |
TCT-16 |
TCT-20 |
TCT -25 |
TCT -40 |
TCT -50 |
TCT-63 |
||
Short-time thermal current It, Ah |
16 |
20 |
25 |
40 |
50 |
63 |
||
Rated insulation voltage Ui, V |
415 |
440 |
440 |
500 |
500 |
500 |
||
Rated impulse voltage Uimp, kV |
6 |
|||||||
Rated power at voltage.kW.in application category |
AC-1/AC-7a (weak inductive loads) |
Rated operating current Ie.A |
16 |
20 |
25 |
40 |
50 |
63 |
230 V |
3 |
3.8 |
4.5 |
8.4 |
10,5 |
13 |
||
400 V |
10.5 |
13 |
16 |
25 |
33 |
40 |
||
AC-3/AC-7b (highly induc tive loads) |
Rated operating current Ie.A |
6 |
7 |
9 |
22 |
27 |
30 |
|
230 B |
1 |
1 |
1.3 |
3.7 |
4.5 |
5 |
||
400 B |
3 |
3.6 |
4.5 |
11.3 |
13.7 |
15 |
||
Control coil voUage. Uc.V |
- + General
-
TOTCT-63 Contactors can be used to remote control applications in alternative networks:
1.lighting,heating,ventilation,roller blinds,sanitary hot water.
2.Mechanical ventilation Systems
3.Load-shedding of non-priority circuits
- + Feature
-
- Circumstance temperature -5°C ~ +40°C, average temperature within 24h not exceeding +35°C.
- Altitude above sea level less than 2000 m.
- Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
- Installation class II
- Pollution class 2.
- Installation method DIN Rail mounting type.
- Product shall be vertically mounted onto standard Din rail 35mm.
- + Technical Data
-
Contactor version
TCT-16
TCT-20
TCT -25
TCT -40
TCT -50
TCT-63
Short-time thermal current It, Ah
16
20
25
40
50
63
Rated insulation voltage Ui, V
415
440
440
500
500
500
Rated impulse voltage Uimp, kV
6
Rated power at voltage.kW.in application category
AC-1/AC-7a (weak inductive loads)
Rated operating current Ie.A
16
20
25
40
50
63
230 V
3
3.8
4.5
8.4
10,5
13
400 V
10.5
13
16
25
33
40
AC-3/AC-7b (highly induc
tive loads)
Rated operating current Ie.A
6
7
9
22
27
30
230 B
1
1
1.3
3.7
4.5
5
400 B
3
3.6
4.5
11.3
13.7
15
Control coil voUage. Uc.V