English English 
  • Русский Русский
  • Русский Español
TONGOU ElectricalTONGOU ElectricalTONGOU ElectricalTONGOU Electrical
For More Information
English English 
  • Русский Русский
  • Русский Español
Menu
  • HOME
  • ABOUT US
    • Certificate
    • Exhibition
    • Close
  • Products
    • Distribution Apparatus
        • 92TOB01-32 240V 10A 30mA RCBO Residual Current Circuit Breaker with Overcurrent ProtectionRCBO
        • MCCBMCCB
        • TOMC5-63 3KA 110V 220V Curve C 2P 40A Mini Circuit Breaker MCBMCB
        • 2P 16A 2NO CE CB Din Rail Household Modular Contactor AC 220V/230VModular Contactor
        • 1-7-300x300SPD
        • TORD5-63 2P 16A 30mA Electromagnetic Type Residual Current Circuit Breaker RCCB RCDRCCB/RCD/ELCB
        • IP67 120*120*70 mm waterproof junction box TO-M3Junction Box
        • TOBB-63 Copper Busbar for Distribution Box MCB connectionBusbar
        • TOD10-100 Main Switch Function Disconnector Switch Isolator BreakerDisconnector
        • flush mounting distribution consumer unit 63A 2P RCD circuit breaker protection metal base boxConsumer Unit
    • Industrial Control
        • TOC2XN-D25 Coil 220V 3P 1NC 25A AC ContactorIndustrial Contactor
    • Close
  • Services
    • News
    • FAQs
    • Catalogue
    • Import Duty-Free
    • Close
  • Contact
elcbhot1
  • RCCB/RCD
  • Miniature Circuit breaker
  • EV Charging Power System
  • Products

    Home Product TOMC7-63 2P 50A DC Mini Circuit Breaker for Solar Energy MCB

    Your Selection

    • Distribution Apparatus
      • MCB
        • DC MCB
        • AC MCB
      • RCCB/RCD/ELCB
      • RCBO
      • MCCB
      • SPD
        • AC SPD
        • DC SPD
      • Solar PV Fuse
      • Modular Contactor
      • Consumer Unit
      • Distribution Box
      • Junction Box
      • Copper Busbar
      • Busbar
    • Industrial Control
      • Industrial Contactor
    • TOMC7-63 2P 50A DC Mini Circuit Breaker for Solar Energy MCB
    • TOMC7-63 2P 50A DC Mini Circuit Breaker for Solar Energy MCB
    • TOMC7-63 2P 50A DC Mini Circuit Breaker for Solar Energy MCB
    • TOMC7-63 2P 50A DC Mini Circuit Breaker for Solar Energy MCB
    • TOMC7-63 2P 50A DC Mini Circuit Breaker for Solar Energy MCB
    TOMC7-63 2P 50A DC Mini Circuit Breaker for Solar Energy MCB TOMC7-63 2P 50A DC Mini Circuit Breaker for Solar Energy MCB TOMC7-63 2P 50A DC Mini Circuit Breaker for Solar Energy MCB TOMC7-63 2P 50A DC Mini Circuit Breaker for Solar Energy MCB TOMC7-63 2P 50A DC Mini Circuit Breaker for Solar Energy MCB
    • 5 years warranty
    • Technical PDF

    TOMC7-63 2P 50A DC Mini Circuit Breaker for Solar Energy MCB

    DC 2P 50A MCB TOMC7DC-63, 50-ampere current rating, excellent breaking capability of 3kA, and B, C and D curves are optional to meet the different needs of applications.1.Protection against both overload and short circuit.

    1.Protection against both overload and short circuit

    2.Contact position indication

    3.Applicable to terminal and pin/fork type Busbar connection

    4.Easy mounting onto 35mm DIN rail

    Categories: DC MCB, MCB
    • Description
    • Reviews (0)

    Description

    • General
    • Feature
    • Technical Data
    • Dimension
    • Inquiry

    DC 2P 50A MCB TOMC7-63 is used for overload and short circuit protection of lighting, power distribution lines and equipment in office buildings, residences and similar buildings, and can also be used for infrequent on-off operations and conversion of lines. Mainly used in various places such as industry, commerce, high-rise and civil residence. DC 2P 50A MCB TOMC7-63s break the circuit by mechanically separating the movable contact and the fixed contact of the miniature circuit breaker. When closing, the moving contact and the fixed contact are closed by the opposite mechanical movement.

    1. MCB is for non-professional operation by those untrained, and no maintenance is required
    2. Satisfying conditions and applications as mentioned above,MCB with “ON-OFF” indicating device is considered suitable for isolation function.
    3. Particular devices such as surge protective devices,surge arrester etc are recommended to install at upstream line to MCB as precaution against potential surge voltage and current occurring at its power input side.
    4. Appropriate tripping curve being chosen and properly installed, MCB trips and switches off its protected circuit in case of fault, and thus provides protection against electric shock.

    TONGOU Solar system DC MCB, apply to rating current 50A or less. It is mainly used for overloading and short circuit protection in DC distribution system equipment and electric equipment. It can be widely used in electric, post, traffic, mining enterprise and different kinds of fields.

    1.Protection against both overload and short circuit

    2.Contact position indication

    3.Applicable to terminal and pin/fork type Busbar connection

    4.Easy mounting onto 35mm DIN rail

    Packaging & Delivery

    Selling Units: Single item
    Single package size: 9.5X4X8.2 cm
    Single gross weight: 0.250 kg
    Lead Time :
    Quantity(Pieces) 1 – 60 >60
    Est. Time(days) 3 To be negotiated
    Model Name TOMC7-63
    Pole No: 2
    Rated voltage: DC 550V
    Rated current(A): 50
    Tripping curve: B C D
    Rated short-circuit capacity(lcn): 6KA
    Rated frequency: 50/60Hz
    Energy limiting class: 3
    Rated impulse withstand voltage: 6.2kV
    Electro-mechanical endurance: ≥ 6000
    Contact position indication
    Connection terminal: Screw terminal / Pillar terminal with calmp
    Connection capacity: Rigid conductor up to 25mm²
    Fastening torque: 2.0Nm
    Installation: On symmetrical DIN rail 35mm / Panel mounting

     

    Environment

    Standards IEC 60947-2, IEC 60898-1, EN60898-1 , AS/NES 60898.1
    IP degree of protection IP40 for modular enclosure conforming to IEC 60529
    IP20 conforming to IEC 60529
    Operating altitude 2000 m
    Ambient air temperature for operation -35°Cto +70°C
    TOMC7-63 6KA mini circuit breaker Installation dimensio

    + General

    DC 2P 50A MCB TOMC7-63 is used for overload and short circuit protection of lighting, power distribution lines and equipment in office buildings, residences and similar buildings, and can also be used for infrequent on-off operations and conversion of lines. Mainly used in various places such as industry, commerce, high-rise and civil residence. DC 2P 50A MCB TOMC7-63s break the circuit by mechanically separating the movable contact and the fixed contact of the miniature circuit breaker. When closing, the moving contact and the fixed contact are closed by the opposite mechanical movement.

    1. MCB is for non-professional operation by those untrained, and no maintenance is required
    2. Satisfying conditions and applications as mentioned above,MCB with “ON-OFF” indicating device is considered suitable for isolation function.
    3. Particular devices such as surge protective devices,surge arrester etc are recommended to install at upstream line to MCB as precaution against potential surge voltage and current occurring at its power input side.
    4. Appropriate tripping curve being chosen and properly installed, MCB trips and switches off its protected circuit in case of fault, and thus provides protection against electric shock.

    + Feature

    TONGOU Solar system DC MCB, apply to rating current 50A or less. It is mainly used for overloading and short circuit protection in DC distribution system equipment and electric equipment. It can be widely used in electric, post, traffic, mining enterprise and different kinds of fields.

    1.Protection against both overload and short circuit

    2.Contact position indication

    3.Applicable to terminal and pin/fork type Busbar connection

    4.Easy mounting onto 35mm DIN rail

    Packaging & Delivery

    Selling Units: Single item
    Single package size: 9.5X4X8.2 cm
    Single gross weight: 0.250 kg
    Lead Time :
    Quantity(Pieces) 1 – 60 >60
    Est. Time(days) 3 To be negotiated
    + Technical Data
    Model Name TOMC7-63
    Pole No: 2
    Rated voltage: DC 550V
    Rated current(A): 50
    Tripping curve: B C D
    Rated short-circuit capacity(lcn): 6KA
    Rated frequency: 50/60Hz
    Energy limiting class: 3
    Rated impulse withstand voltage: 6.2kV
    Electro-mechanical endurance: ≥ 6000
    Contact position indication
    Connection terminal: Screw terminal / Pillar terminal with calmp
    Connection capacity: Rigid conductor up to 25mm²
    Fastening torque: 2.0Nm
    Installation: On symmetrical DIN rail 35mm / Panel mounting

     

    Environment

    Standards IEC 60947-2, IEC 60898-1, EN60898-1 , AS/NES 60898.1
    IP degree of protection IP40 for modular enclosure conforming to IEC 60529
    IP20 conforming to IEC 60529
    Operating altitude 2000 m
    Ambient air temperature for operation -35°Cto +70°C
    + Dimension
    TOMC7-63 6KA mini circuit breaker Installation dimensio
    + Inquiry

    Reviews

    There are no reviews yet, would you like to submit yours?

    Be the first to review “TOMC7-63 2P 50A DC Mini Circuit Breaker for Solar Energy MCB” Cancel reply

    *

    *

    PreviousNext

    Related Products

    • TOMC3-63 3KA Curve C 1P 63A Mini Circuit Breaker MCB

      TOMC3-63 3KA Curve C 1P 63A Mini Circuit Breaker MCB

      Read more Show Details
    • TOMC3-63 3KA Curve C AC Voltage 110v 220v 2P 25A MCB Miniature Circuit Breaker

      TOMC3-63 3KA Curve C AC Voltage 110v 220v 2P 25A MCB Miniature Circuit Breaker

      Read more Show Details
    • TOMC7-63 1P 6-63A DC Mini Circuit Breaker for Solar Energy MCB

      TOMC7-63 1P 6-63A DC Mini Circuit Breaker for Solar Energy MCB

      Read more Show Details
    • TOMC3-63 3KA 110V 220V Curve C 2P 63A Mini Circuit Breaker MCB

      TOMC3-63 3KA 110V 220V Curve C 2P 63A Mini Circuit Breaker MCB

      Read more Show Details
    • TOMC7-63 2P 20A DC Mini Circuit Breaker for Solar Energy MCB

      TOMC7-63 2P 20A DC Mini Circuit Breaker for Solar Energy MCB

      Read more Show Details

    About US

    Established in 1993, Tongou electrical focus on the electricity safety products for household, commercial, industrial and similar installations, Such as Miniature Citcuit Breaker (MCB), Residual Current Circuit Breaker(RCCB), Residual Current Circuit Breakers with Over-current Protection(RCBO), Switch-Disconnector, Distribution Box, Moulded case circuit breaker(MCCB), air circuit breaker(ACB), AC Contactor, Magnetic Starter, Motor Protection Circuit Breaker and Thermal Relay etc.

    PRODUCT LIST

    Distribution Apparatus

    Industrial Control

    Consumer Unit

    MCB

    MCCB

    Modular Contactor

    RCBO

    RCCB/RCD/ELCB

    Industrial Contactor

    Thermal Relay

    Contact US

    map_76.968105065666px_1152927_easyicon.net

    Manufacturer Address

    Paidong Industrial Zone Qiligang,Yueqing City,Zhejiang province,China.

    phone

    Phone No

    +86-577-62676885

    mail_179.02097902098px_1188260_easyicon.net

    E-Mail

    [email protected]

    dh

    Mobile

    +86-15325075111

    whatsapp

    WhatsApp

    +86-15325075111

    Onlie Store(Sample Order):
    sumaitong EBAY amazon
    Skype QQ Wechat
    Copyrights © TONGOU Electrical
    • HOME
    • ABOUT US
      • Certificate
      • Exhibition
    • Products
      • Distribution Apparatus
        • RCBO
        • MCB
        • MCCB
        • Modular Contactor
        • RCCB/RCD/ELCB
        • Consumer Unit
        • Junction Box
        • Busbar
        • Disconnector
      • Industrial Control
        • Industrial Contactor
    • Services
      • FAQs
      • PDF DOWNLOAD
      • Import Duty-Free
    • News
    • Contact
    TONGOU Electrical